Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首頁 > Home > Industrial Safety Products > Safety interlock switch > RFID Electromagnetic Locking Safety Door Switch
D3SL-T/RFID electromagnetic locking type
1.png

·Electromagnetic force locking 500N

·Adopt a small plane "electromagnetic" locking structure.

·Support 16 to 20 cascaded connections.

·Design of permanent magnet in matcher

·Small body, simple installation

·Full-angle eye-catching indicator light

·No abrasive powder will be produced.

·IP65/IP67 protection


D3SL-T/RFID Series Selection Table

Locking mode

deploy

model

Output mode

coded system

Electromagnetic locking

normalized form

D3SL-T-DB-N2

NPN

universal coding

D3SL-T-DB-N1

NPN

Unique coding

D3SL-T-DB-P2

PNP

universal coding

D3SL-T-DB-P1

PNP

Unique coding

Advanced type

D3SL-T-DG-N2

NPN

universal coding

D3SL-T-DG-N1

NPN

Unique coding

D3SL-T-DG-P2

PNP

universal coding

D3SL-T-DG-P1

PNP

Unique coding


Technical parameters of D3SL-T/RFID

type

Hinged door

small-sized

M12 connector

normalized form

High functional type

working distance

Sao(off-0n)

4mm

Sar(on-0ff)

4mm

Response time

Lock → release

155ms

Release → lock

155ms

Detection → Non-detection

20ms+2ms* (Number of cascaded connections -1)

Non-detection → detection

300ms+25ms* (Number of cascaded units -1)

Control output

(OSSD output)

Output mode

Transistor output "2

Maximum load current

150mA

Residual voltage (on)

Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

OFF voltage

Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

leakage current

Up to 0.5mA

Maximum load capacity

0.8uF

Load connection resistance

Max. 2.5 Euro

AUX output

(Non-safety system output)

Output mode

Transistor output

Maximum load current

50mA

Residual voltage (ON)

Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

external input

(Short-circuit current)

Safety input

About 1.5 max 2

Locking control input OSSD action switching input

About 2.5 mA

Reset /EDM input

About 5mA (high functional type only)

EDM select input

About 2.5 mA (high functional type only)

Power Supply 

Power supply voltage

24 VDC 10% including ripple (P-P)10% Class2

consumed power

<5W

protective circuit

Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

Environmental resistance

Enclosure protection grade

IP65/67(IEC60529)

Operating ambient temperature

20 degrees below zero to 55 degrees without freezing.

Storage ambient temperature

25 degrees below zero to 70 degrees without freezing.

Using ambient humidity

5% to 95%RH

Storage environment humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

Applicable standards

ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


Model description of safety switch

 1728548977520914.png 



hookup

Standard type (NPN, cascade)

Standard (PNP, cascade)

1719978292858022.png

Standard type (NPN, cascade)

1719978426648983.png

Standard (PNP, cascade)

1719978725470017.png

Functional (NPN, cascade)

Functional (PNP, cascade)

1719979076106539.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

High functional type (NPN, cascade)

1719979521976024.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

Functional (PNP, cascade)

1719979875434469.png

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

S: reset switch

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

*1. Make ?EDM and reset: wire as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch


Indication of indicator light

1719983442751425.png


Product ruler diagram

1719983681983392.png


Selection Method of Safety Switch D3SL-T/RFID Series

1728618489514684.png



Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 国产午夜鲁丝片av无码免费 | 色呦呦在线免费观看 | 国产精品一国产av麻豆 | 久草在线综合 | 亚洲成人一区在线 | 日韩二三区 | 欧美在线免费 | 天天做天天大爽天天爱 | 在线亚洲视频网站www色 | 午夜高清在线无码 | 亚洲欧美人色综合婷婷久久 | 一区二区视频在线观看免费 | 国产成人av无码精品天堂 | 国产精品久久久久久无人区 | 麻豆视频91 | 国产精品va在线 | 国产成人综合久久二区 | 国产97视频人人做人人爱 | 国产精品乱码高清在线观看 | 亚洲另类在线制服丝袜国产 | 伊人888| 久久久久久人妻精品一区 | 亚洲东方av | 亚洲午夜久久久久久久久久 | 国产a∨精品一区二区三区不卡 | 欧美成人无码a区视频在线观看 | 日韩中文字幕在线看 | 欧美久久久久久久久久久久久久 | 国产福利一区二区三区在线视频 | 国产精品成人免费 | 无码综合天天久久综合网 | 手机在线不卡av | 91无限观看 | 少妇奶水亚洲一区二区观看 | 国产精品人八做人人女人a级刘 | 高潮又爽又黄又无遮挡动态图 | 无码r级限制片在线观看 | 免费国精产品—品二品 | 极品尤物在线观看 | 亚洲 欧美 日韩 综合aⅴ视频 | 国产精品无码av无码 | a级黄色录像| 国产一卡2卡三卡4卡免费网站 | 淫片网站 | 日韩色婷婷 | 婷婷六月丁香缴 清 | 奇米影视色777四色在线首页 | 奇米色欧美一区二区三区 | 超碰97成人 | 久草资源网站 | 免费一区二区视频 | 爱情岛亚洲论坛入口首页 | 国产乱码精品一区二区蜜臀 | 成人欧美一区二区 | 无码东京热一区二区三区 | 国产人妻熟女ⅹxx高跟丝袜写真 | 亚洲4区| 在线看成人片 | 直接看av的网站 | 欧美怡红院视频一区二区三区 | 国产欧洲色婷婷久久99精品91 | 久久99精品国产 | 男人的天堂网在线 | 亚洲高清在线播放 | 日韩极品视频在线观看 | 成人亚洲a片v一区二区三区麻豆 | 婷婷嫩草国产精品一区二区三区 | 最新无码专区视频在线 | 国产又色又爽无遮挡免费软件 | 伊人激情网 | 色综合一区 | 国产精品久久久久久久福利 | 五月天丁香久久 | 欧洲妇女成人淫片aaa视频 | 爱弓凉在线视频一区二区 | 一区二区三区在线免费视频 | 欧美日韩亚洲综合 | 成人午夜又粗又硬又大 | 久爱视频在线 | 国产成人精品日本亚洲77美色 | 色一情一区二 | 国产午夜片无码区在线观看爱情网 | 国内外免费激情视频 | 五月婷婷久久草 | 1000部无遮挡拍拍拍免费视频观看 | 精品女同一区二区三区在线 | 九九热在线视频观看这里只有精品 | 美女隐私免费网站 | 欧美交换配乱吟粗大25p | 色 综合 欧美 亚洲 国产 | 国产中文字字幕乱码无限 | 国产精品黄 | 一级久久久久久久 | 日本少妇激情舌吻 | 国产又爽又黄又湿免费99 | 先锋影音av资源站av | 亚洲综合三区 | 韩国国产在线 | 青娱乐最新网站 |